107kWh 50kVA Air-Cooled Commercial Battery Storage System for Mid-Size C&I Projects
107kWh Commercial Battery Storage for Mid-Size Projects
Choosing storage capacity is usually the first decision in a commercial energy project — and the one most often made too early. Buyers pick a cabinet from the roof size or the equipment budget, then discover at commissioning that it cannot cover the loads that matter.
The Voltertech BESS-107KWH-50KW-W is the mid-size class in this air-cooled series. It combines 107kWh of LiFePO4 storage with a 50kVA on/off-grid PCS, with up to 38.4kW + 38.4kW of solar input available as an option.
It is sized for sites that have outgrown a 30–60kWh cabinet but do not need a 200kWh-class installation: light industrial plants, larger commercial buildings, processing facilities and distribution centers.
Key Advantages for Mid-Size Projects
How to Choose the Right Storage Capacity
Capacity should come from two numbers, not from a product catalogue. The first is the load that must be supported, in kW. The second is the number of hours that load needs to run without grid power or solar generation.
Multiply them and add a margin for conversion losses and usable depth of discharge. A site needing 25kW of essential load for four hours requires roughly 100kWh of usable energy before allowances — which is exactly the class this cabinet sits in.
Power rating is a separate check. The 50kVA PCS defines what can run at once; the 107kWh battery defines how long. A project can fail on either one.
Where This Capacity Class Fits
Within this series, smaller air-cooled cabinets serve small shops and cold rooms where demand is modest. Larger liquid-cooled cabinets serve factories and grid-scale commercial projects with heavy continuous loads.
The 107kWh / 50kVA class sits between them. It suits a single mid-size site with a defined set of essential loads, where one cabinet can be installed and commissioned without a multi-unit configuration. For distributors, it is also the practical step-up model for customers who started with a smaller system and now need more capacity.
Operating Scenarios
Solar Self-Consumption
Surplus daytime PV charges the battery, which supplies evening loads instead of drawing from the grid.
Backup for Essential Circuits
With off-grid output, selected loads keep operating during grid interruptions, sized from the required runtime.
Peak and Load Management
The cabinet trims short demand peaks during normal operation, improving project economics between outages.
Why the Cycle Rating Matters Here
A system used for self-consumption or peak management cycles almost every day. Over a 15-year design life, that is thousands of charge and discharge cycles — the reason cycle rating belongs in the procurement decision rather than the fine print.
This model is specified at 8000 cycles with air cooling. For a mid-size commercial project, that supports daily operation across the design life, provided the system is sized and installed within its operating conditions.
Core Technical Specifications
Swipe left or right to view the complete specification table.
| Parameter | Specification |
|---|---|
| Model | BESS-107KWH-50KW-W |
| System Type | Air-Cooled Commercial Battery Storage System |
| Battery Chemistry | LiFePO4 |
| Total Capacity | 107kWh |
| Nominal Capacity (Cell) | 280Ah |
| Nominal Voltage | 384V |
| Operating Voltage Range | 312V – 432V |
| Nominal Charge / Discharge Current | 140A |
| PCS Rated Output (On-Grid / Off-Grid) | 50kVA |
| Max. Output Power (Off-Grid) | 55kVA |
| Rated AC Voltage | AC 230/400V, 50/60Hz |
| Rated AC Current (On-Grid) | 73A |
| AC Voltage Harmonic | < 3% |
| Max. PV Input Power (2 Channels) | 38.4kW + 38.4kW (Optional) |
| Max. PV Input Current (2 Channels) | 64A + 64A |
| Maximum PV Voltage | 850V |
| Starting Voltage | 250V |
| MPPT Voltage Range | 200V – 800V |
| Cooling Mode | Air Cooling |
| Cycle Life / Calendar Life | 8000 Cycles / 15 Years |
| Operating Temperature | -20°C to +50°C |
| Storage Temperature | -30°C to +60°C |
| Operating Humidity | 5% – 95% |
| Working Altitude | ≤ 2000m |
| Enclosure Protection | IP54 |
| Communication | LAN / RS485 / CAN |
| Dimensions (L × W × H) | 1203 × 900 × 2350mm |
| Net Weight | Approx. 1260kg |
System Planning and Integration
Typical Mid-Size Applications
Light Industrial and Processing Plants
Sites with moderate continuous loads and defined essential circuits, where a single cabinet can cover evening operation or outage protection.
Commercial Buildings and Distribution Centers
Larger offices, warehouses and logistics hubs managing daytime solar surplus and evening demand from one system.
Agro-Processing and Cold Chain Facilities
Processing sites with refrigeration and machinery loads that need both daytime solar support and dependable backup.
Regional Distributor and EPC Projects
A repeatable mid-size configuration for installers serving several similar commercial sites in the same market.
Frequently Asked Questions
Q1. How do I know if 107kWh is the right capacity for my project?
Multiply the essential load in kW by the required hours of coverage, then add a margin for conversion losses and usable depth of discharge. If the result is around 100kWh, this class is a reasonable starting point. We can review your load list before you decide.
Q2. What kind of site typically needs a 50kVA / 107kWh system?
Mid-size commercial and light industrial sites that have outgrown a 30–60kWh cabinet but do not require a 200kWh-class installation. The 50kVA rating covers simultaneous loads; the 107kWh covers duration.
Q3. How long can 107kWh keep a site running?
It depends on the load. At a 25kW essential load, a little over four hours before allowances; at a reduced 10kW load, considerably longer. Actual runtime depends on operating conditions and system configuration.
Q4. How much solar can be connected?
Up to 38.4kW + 38.4kW across two PV channels, with 64A + 64A input current and a 200–800V MPPT range. String design should be checked against these limits before the array layout is fixed.
Q5. Is solar input required, or can the system work on grid and battery only?
PV input is optional. The system also operates with grid charging and battery discharge, which suits sites planning to add solar in a later phase.
Q6. Can the system provide off-grid backup?
Yes. The PCS supports off-grid output with 50kVA rated and 55kVA maximum power. Which circuits can be supported should be defined during system design from the essential load list.
Q7. What information is needed for a quotation?
Please provide the destination country, interval consumption data or an essential load list, required backup hours, planned PV capacity if any, site voltage, and the required quantity. A single-line diagram helps with the grid connection review.
Not Sure Which Storage Capacity Fits Your Project?
Voltertech supplies air-cooled commercial battery storage for distributors, EPC contractors and mid-size commercial projects. Send us your load list or interval consumption data and we will help confirm the right capacity class before you order.
OEM and ODM options are available for bulk orders and regional distribution programs.
Request 107kWh BESS Details & Quotation107kWh Commercial Battery Storage System
,50kVA Commercial Energy Storage System
,Air-Cooled Commercial BESS
-
1.725MW 10kV Transformer-Isolated PCS Container Power Conversion System for Medium Voltage Substation Tie-In
Voltertech 1.725MW / 10kV AC-side PCS container with transformer isolation, 1000–1500V DC range and 1725kVA AC output. Built for EPC teams planning MV switchgear interfaces, cable routing, electrical protection and substation tie-in documentation. -
30kWh 15kVA Commercial BESS with STS: Commercial Battery Energy Storage System for Backup Load Planning
Voltertech 30kWh LiFePO4 commercial BESS with 15kVA rated AC output, STS function and 16.5kVA maximum off-grid output. Air-cooled IP54 cabinet with LAN/RS485/CAN interfaces for small commercial backup load planning. -
233kWh Liquid Cooled Commercial BESS for Grid-to-Off-Grid Commercial Energy Storage System
Voltertech 233kWh liquid-cooled C&I BESS with optional 100kW PCS, 20ms STS handover, grid/off-grid modes and 832V LiFePO4 battery. Designed for EPC teams planning commercial power transfer and backup load circuits.