Product Summary
107kWh air-cooled commercial battery storage for mid-size industrial and business projects. 50kVA on/off-grid PCS, 76.8kW optional PV input, 8000 cycles, 384V LiFePO4, IP54. Solar-led daytime power with overnight backup. OEM/ODM available.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: IEC62477-1 , IEC61000-6/2/4 , UN3536
Model Number: BESS-107KWH-50KW-W-4
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

107kWh Commercial Battery Storage for Mid-Size Projects

Choosing storage capacity is usually the first decision in a commercial energy project — and the one most often made too early. Buyers pick a cabinet from the roof size or the equipment budget, then discover at commissioning that it cannot cover the loads that matter.

The Voltertech BESS-107KWH-50KW-W is the mid-size class in this air-cooled series. It combines 107kWh of LiFePO4 storage with a 50kVA on/off-grid PCS, with up to 38.4kW + 38.4kW of solar input available as an option.

It is sized for sites that have outgrown a 30–60kWh cabinet but do not need a 200kWh-class installation: light industrial plants, larger commercial buildings, processing facilities and distribution centers.

Key Advantages for Mid-Size Projects

107kWh / 50kVA Enough capacity to cover a meaningful share of a site's daily load, with rated output for simultaneous commercial and light industrial equipment.
8000 Cycles The highest cycle rating in this air-cooled series, matching the demands of daily charge and discharge operation.
Optional 76.8kW Solar Two PV channels with 64A + 64A input current allow a sizeable array to be connected directly to the cabinet.

How to Choose the Right Storage Capacity

Capacity should come from two numbers, not from a product catalogue. The first is the load that must be supported, in kW. The second is the number of hours that load needs to run without grid power or solar generation.

Multiply them and add a margin for conversion losses and usable depth of discharge. A site needing 25kW of essential load for four hours requires roughly 100kWh of usable energy before allowances — which is exactly the class this cabinet sits in.

Power rating is a separate check. The 50kVA PCS defines what can run at once; the 107kWh battery defines how long. A project can fail on either one.

Sizing Note: Start from interval consumption data or a load list, not from the size of the rooftop array. Many projects buy too much battery because the PV array is large, when the actual limiting factor is the evening load.

Where This Capacity Class Fits

Within this series, smaller air-cooled cabinets serve small shops and cold rooms where demand is modest. Larger liquid-cooled cabinets serve factories and grid-scale commercial projects with heavy continuous loads.

The 107kWh / 50kVA class sits between them. It suits a single mid-size site with a defined set of essential loads, where one cabinet can be installed and commissioned without a multi-unit configuration. For distributors, it is also the practical step-up model for customers who started with a smaller system and now need more capacity.

Operating Scenarios

Solar Self-Consumption

Surplus daytime PV charges the battery, which supplies evening loads instead of drawing from the grid.

Backup for Essential Circuits

With off-grid output, selected loads keep operating during grid interruptions, sized from the required runtime.

Peak and Load Management

The cabinet trims short demand peaks during normal operation, improving project economics between outages.

Why the Cycle Rating Matters Here

A system used for self-consumption or peak management cycles almost every day. Over a 15-year design life, that is thousands of charge and discharge cycles — the reason cycle rating belongs in the procurement decision rather than the fine print.

This model is specified at 8000 cycles with air cooling. For a mid-size commercial project, that supports daily operation across the design life, provided the system is sized and installed within its operating conditions.

Core Technical Specifications

Swipe left or right to view the complete specification table.

Parameter Specification
Model BESS-107KWH-50KW-W
System Type Air-Cooled Commercial Battery Storage System
Battery Chemistry LiFePO4
Total Capacity 107kWh
Nominal Capacity (Cell) 280Ah
Nominal Voltage 384V
Operating Voltage Range 312V – 432V
Nominal Charge / Discharge Current 140A
PCS Rated Output (On-Grid / Off-Grid) 50kVA
Max. Output Power (Off-Grid) 55kVA
Rated AC Voltage AC 230/400V, 50/60Hz
Rated AC Current (On-Grid) 73A
AC Voltage Harmonic < 3%
Max. PV Input Power (2 Channels) 38.4kW + 38.4kW (Optional)
Max. PV Input Current (2 Channels) 64A + 64A
Maximum PV Voltage 850V
Starting Voltage 250V
MPPT Voltage Range 200V – 800V
Cooling Mode Air Cooling
Cycle Life / Calendar Life 8000 Cycles / 15 Years
Operating Temperature -20°C to +50°C
Storage Temperature -30°C to +60°C
Operating Humidity 5% – 95%
Working Altitude ≤ 2000m
Enclosure Protection IP54
Communication LAN / RS485 / CAN
Dimensions (L × W × H) 1203 × 900 × 2350mm
Net Weight Approx. 1260kg

System Planning and Integration

Load and Interval Data
Use electricity bill data or a metered load profile to identify the essential load in kW and the hours storage must cover.
Power Check
Confirm simultaneous demand and motor starting currents against the 50kVA rating before finalizing the configuration.
Solar Array
Where PV is planned, verify string voltage and current against the 200–800V MPPT range and 64A channel limit. PV input is optional.
Site Conditions
Allow for the 1260kg cabinet weight, 1203 × 900mm footprint, ventilation clearance for air cooling and protection beyond the IP54 rating.
Monitoring
LAN, RS485 and CAN interfaces support coordination with site energy management and remote monitoring.

Typical Mid-Size Applications

Light Industrial and Processing Plants

Sites with moderate continuous loads and defined essential circuits, where a single cabinet can cover evening operation or outage protection.

Commercial Buildings and Distribution Centers

Larger offices, warehouses and logistics hubs managing daytime solar surplus and evening demand from one system.

Agro-Processing and Cold Chain Facilities

Processing sites with refrigeration and machinery loads that need both daytime solar support and dependable backup.

Regional Distributor and EPC Projects

A repeatable mid-size configuration for installers serving several similar commercial sites in the same market.

Frequently Asked Questions

Q1. How do I know if 107kWh is the right capacity for my project?

Multiply the essential load in kW by the required hours of coverage, then add a margin for conversion losses and usable depth of discharge. If the result is around 100kWh, this class is a reasonable starting point. We can review your load list before you decide.

Q2. What kind of site typically needs a 50kVA / 107kWh system?

Mid-size commercial and light industrial sites that have outgrown a 30–60kWh cabinet but do not require a 200kWh-class installation. The 50kVA rating covers simultaneous loads; the 107kWh covers duration.

Q3. How long can 107kWh keep a site running?

It depends on the load. At a 25kW essential load, a little over four hours before allowances; at a reduced 10kW load, considerably longer. Actual runtime depends on operating conditions and system configuration.

Q4. How much solar can be connected?

Up to 38.4kW + 38.4kW across two PV channels, with 64A + 64A input current and a 200–800V MPPT range. String design should be checked against these limits before the array layout is fixed.

Q5. Is solar input required, or can the system work on grid and battery only?

PV input is optional. The system also operates with grid charging and battery discharge, which suits sites planning to add solar in a later phase.

Q6. Can the system provide off-grid backup?

Yes. The PCS supports off-grid output with 50kVA rated and 55kVA maximum power. Which circuits can be supported should be defined during system design from the essential load list.

Q7. What information is needed for a quotation?

Please provide the destination country, interval consumption data or an essential load list, required backup hours, planned PV capacity if any, site voltage, and the required quantity. A single-line diagram helps with the grid connection review.

Not Sure Which Storage Capacity Fits Your Project?

Voltertech supplies air-cooled commercial battery storage for distributors, EPC contractors and mid-size commercial projects. Send us your load list or interval consumption data and we will help confirm the right capacity class before you order.

OEM and ODM options are available for bulk orders and regional distribution programs.

Request 107kWh BESS Details & Quotation
Product Details
Highlight:

107kWh Commercial Battery Storage System

,

50kVA Commercial Energy Storage System

,

Air-Cooled Commercial BESS

Application: Mid-Size Commercial & Industrial
Target Buyers: EPC, Distributors, Installers
Capacity Class: 107kWh / 50kVA PCS
Site Types: Plant / Warehouse / Processing
PV Input: 38.4kW + 38.4kW Optional
Cooling: Air Cooling