12.8V 100Ah LiFePO4 Lithium Battery IP65 100A Discharge For Inverter Systems

Product Summary
12.8V 100Ah IP65 LiFePO4 Battery with 100A Discharge for Inverter Systems This 12.8V 100Ah IP65 LiFePO4 battery is designed for compatible low-voltage inverter and UPS systems that require a compact 1.28kWh battery with clearly defined charge and discharge limits. Electrical Matching Comes Before ...
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: MSDS , UN38.3
Model Number: PB-1KWH-12.8V-Q-2
Trading Properties
Minimum Order Quantity: 2 Units
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

12.8V 100Ah IP65 LiFePO4 Battery with 100A Discharge for Inverter Systems

This 12.8V 100Ah IP65 LiFePO4 battery is designed for compatible low-voltage inverter and UPS systems that require a compact 1.28kWh battery with clearly defined charge and discharge limits.

Electrical Matching Comes Before Inverter Power

Battery capacity and inverter power describe different parts of the system. The 1.28kWh energy rating indicates how much nominal energy is stored, while the inverter rating determines the available AC output.

The inverter’s battery-side current must remain compatible with the 100A continuous discharge limit. A higher-wattage inverter may exceed this current at low battery voltage even when the connected AC load appears moderate.

Voltage Requirement

The connected equipment must support a 12.8V lithium battery operating between 10.0V and 14.6Vdc.

Charging Requirement

Continuous charging should not exceed 50A, and the charging profile should support a 14.0V floating-charge setting.

Current Planning for DC Loads

The battery supports 100A of continuous discharge. Battery cables, M8 terminals, breakers and fuses should be selected according to the configured current, cable length and allowable voltage drop.

A 150A pulse rating is listed for one second. This temporary value may accommodate a brief compatible demand, but it should not be used as the continuous design current.

Motor-driven loads can require temporary startup current. Their suitability must be checked against the inverter surge capability and the battery’s pulse limit.

BMS Protection and External Protection

The battery-management system includes overcharge, overdischarge, overcurrent, short-circuit and overtemperature protection. These functions help keep battery operation within its documented limits.

BMS protection does not replace a correctly rated external fuse, breaker or disconnect device. External protection and appropriate cable sizing remain necessary.

Compact Integration Data

Battery Energy Platform 12.8V / 100Ah / 1.28kWh
Battery Voltage Window 10.0–14.6Vdc
Charging Parameters 14.0V Float / 50A Continuous Maximum
Discharge Parameters 100A Continuous / 150A for 1 Second
BMS Protection Coverage Overcharge / Overdischarge / Overcurrent / Short Circuit / Overtemperature
Mechanical Data 331 × 171 × 218mm / 10kg Net
Environmental Limits IP65 / -10°C to 50°C / Non-Condensing
Storage Conditions 0°C to 30°C / Six Months at 25°C
Documentation UN38.3 / MSDS

Low-Voltage Inverter Battery FAQ

Can the battery work with any 12V inverter?

No. The inverter voltage window, charging profile and maximum battery current must be compatible.

Is 100A the recommended discharge current?

It is the maximum continuous battery limit. The actual current may be lower according to the system design.

Can the battery support a motor load?

Only after the motor startup demand, inverter surge rating and one-second battery pulse limit are checked.

Does IP65 protect the terminal connection automatically?

No. Terminal covers, cable lugs and external connections still require appropriate protection.

What inverter data should be submitted?

Provide the inverter model, battery-voltage range, maximum charge current and expected continuous load.

12V Inverter Compatibility Check

Need to check current demand and charger settings?

Send the Inverter Specification for Review

Product Details
Highlight:

LiFePO4 Lithium Battery IP65

,

LiFePO4 Lithium Battery 100A

,

LiFePO4 Battery For Inverter System

Battery Operating Range: 10.0 – 14.6Vdc
Floating - Charge Setting: 14.0Vdc
Maximum Continuous Charge: 50A
Maximum Continuous Discharge: 100A
Temporary Pulse Capability: 150A For 1 Second
Integrated BMS Protection: Five Protection Functions
Operating Temperature: -10°C To 50°C
Transport Documentation: UN38.3 / MSDS

Customer Service

Related Products
  • 5.12kWh 51.2V Wall Mount LiFePO4 Battery With Parallel Expansion

    5.12kWh 51.2V Wall Mounted LiFePO4 Battery with Parallel Expansion This 5.12kWh wall mounted LiFePO4 battery combines a compact 51.2V energy-storage platform with integrated BMS protection and flexible communication options. It is suitable for residential solar storage, UPS backup, communication ...
  • 6kW 16kWh All In One Energy Storage System For Long Duration Home Backup

    6kW 16kWh All In One Energy Storage System for Long Duration Home Backup Long-Duration Energy Storage in One Integrated System This 6kW 16kWh all in one energy storage system combines inverter output, battery storage, MPPT solar charging, local control and remote monitoring within one coordinated ...
  • 8kWh 3.6kW All In One Energy Storage System Residential Solar Battery Storage System

    This 8kWh all in one energy storage system combines a 3.6kW pure sine wave inverter, 7.2kWh usable battery energy, MPPT solar charging, LCD and WiFi monitoring. It supports up to 5kW PV input and 10ms transfer for longer residential backup applications.
Send An Inquiry