2.5MW 10kV Transformer Isolation Power Conversion System Container for High-Density Utility Energy Storage PCS Layouts

Product Summary
The 2.5MW 10kV PCS container packs 2500kW and 2619A DC into a single unit, cutting land, foundations and parallel units for high-density utility storage projects.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: IEC62477-1 , IEC61000-6/2/4 , UN3536
Model Number: BESS-25MW-W-4
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

2.5MW 10kV PCS Container for Compact Grid-Scale Layouts

Utility-scale storage developers with tight sites face a clear trade-off: hit the target plant capacity with more lower-power PCS units, or use fewer high-power units to save land, foundations and parallel wiring. On land-constrained projects, that second option often wins.

The Voltertech 2.5MW 10kV power conversion system container answers that need. It packs 2500kW of rated output and a 1000–1500V DC input with 2619A maximum current into a single container, while sharing the same 5523×2400×2800mm footprint as the 1.25MW class — so capacity doubles without doubling the site area.

With transformer isolation, THD ≤3% at rated power and an adjustable power factor from -1 to +1, plus CAN/RS485 battery communication and Modbus RTU/TCP plus IEC 104 for dispatch, it is built for direct integration into utility SCADA and high-density grid-tied storage plants.

Key Advantages for High-Density Plant Layouts

2.5MW in One Container Doubles the 1.25MW class in the same 5523×2400×2800mm footprint, halving units per MW of plant capacity.
2619A Max. DC Current Supports larger battery blocks with higher charge/discharge current than the 1.25MW or 1.725MW classes.
Fewer Parallel Units Reaching multi-megawatt capacity with fewer containers cuts land, foundations, MV cabling and maintenance points.

How Unit Power Density Cuts Project Cost

Every PCS container added to a plant brings its own foundation, MV cable runs, protection equipment and commissioning work. A 10MW plant, for example, needs eight 1.25MW units but only four 2.5MW units — that is four fewer foundations, four fewer cable runs and four fewer units to maintain. For land-constrained or high-cost sites, the saving in civil works alone can be significant.

Key point: Higher-power PCS units reduce the number of parallel containers per MW of plant capacity. That directly lowers land use, foundation count, MV cabling and long-term maintenance overhead.

Matching Battery Blocks to a 2.5MW PCS

The 1000–1500V DC input with 2619A maximum current gives a DC-side capability of roughly 2.6MW at the upper voltage, so the PCS suits battery blocks rated near 2.4–2.5MW. Confirm the block's voltage and power before finalizing, as an oversized block under-utilizes the PCS and an undersized one limits plant output. Voltertech's 5MWh DC container is a natural pairing for this power class.

Operating Scenarios for the 2.5MW PCS Container

High-density utility storage

Multi-megawatt plants where land or foundation count is the limiting factor, such as urban-edge substations.

Large renewable co-location

Paired with utility-scale PV or wind blocks that need a single high-power conversion stage to the 10kV grid.

Industrial park storage

Compact layouts for industrial parks and commercial campuses that need maximum MW per square metre.

Core Technical Specifications

Swipe left or right to view the complete specification table.

Parameter Specification
DC Voltage Range 1000–1500V
Rated Power (DC side) 2500kW
Max. Current (DC side) 2619A
Rated Output Power (AC side) 2500kVA
Rated AC Voltage 10kV
Rated AC Current 145A
Isolation Mode Transformer isolation
Max. Total Harmonic Distortion ≤3% at rated power
Power Factor -1 to +1 adjustable
Storage Temperature Range -25℃ to +55℃
Operating Temperature Range -25℃ to +50℃
Operating RH 0%–95%
Working Altitude ≤2000m
Dimension (L×W×H) 5523×2400×2800mm
Net Weight ≈15T
Cooling Mode Air cooling
Battery Communication Interface CAN / RS485
Dispatch Communication Interface Modbus RTU / Modbus TCP / IEC 104

System Integration and Project Considerations

The 2.5MW PCS container is supplied as a self-contained conversion unit for AC-side integration. The following points matter for EPCs and system integrators planning a high-density plant.

Medium-voltage tie-in
Connect the 10kV output to the project's MV bus or substation; transformer isolation is integrated in the container.
Dispatch protocols
Modbus RTU/TCP and IEC 104 support integration with plant SCADA and utility control.
Battery communication
CAN/RS485 links to the BMS of the paired DC battery container.
Compact layout
Same footprint as the 1.25MW class, so capacity scales without extra land or foundations per unit.
Site conditions
Rated for -25℃ to +50℃ operation and altitudes up to 2000m; confirm derating for higher sites.

Typical High-Density Applications

Utility peak shaving

High-power PCS containers discharge stored energy during peak demand to flatten load on the medium-voltage grid with fewer units.

Renewable energy firming

Convert large PV or wind blocks into dispatchable 10kV power through paired high-capacity DC battery containers.

Industrial co-location

Land-constrained industrial parks and campuses needing maximum MW per square metre of installed equipment.

Grid frequency regulation

Rapid, adjustable power factor and low THD support frequency response in compact, high-power storage plants.

Frequently Asked Questions

Q1. Is this a complete energy storage system or just a PCS?

It is a power conversion system (PCS) container, not a battery energy storage system. It converts DC power from an external battery block into 10kV AC and must be paired with a battery container to form a complete storage plant.

Q2. How does 2.5MW compare to the 1.25MW and 1.725MW classes?

It delivers the highest power in a single container, with 2619A DC current and a 145A AC rating at 10kV. Despite the higher power, it keeps the same 5523×2400×2800mm footprint as the 1.25MW class, so capacity scales without extra land per unit.

Q3. Can multiple 2.5MW PCS containers run in parallel?

Yes. Multiple units can connect to a shared medium-voltage bus to build multi-megawatt AC-side plants, with each unit handling its own battery block. Fewer units are needed per MW than lower-power classes.

Q4. What battery voltage does it support?

The DC input range is 1000–1500V with a 2619A maximum current. Confirm the battery block's voltage and power match before finalizing.

Q5. What communication protocols are available for dispatch?

Modbus RTU, Modbus TCP and IEC 104 for grid dispatch, plus CAN/RS485 for battery BMS communication.

Q6. What cooling method does this container use?

Air cooling. Note the supplier's datasheet header lists "liquid cooling" while the cooling field states air cooling — please confirm the exact cooling configuration with our engineers before ordering.

Q7. What details do you need for a quotation?

Please provide the battery block voltage and power, total plant capacity, number of units, grid connection voltage, and project location/altitude so we can confirm the correct configuration.

Planning a High-Density Storage Plant?

Tell us your battery block size and total capacity, and we will confirm whether the 2.5MW PCS container — or a parallel arrangement — is the right fit for your project.

Share your project parameters and we will prepare a tailored quotation.

Request 2.5MW PCS Details & Quotation
Product Details
Highlight:

Transformer Isolation PCS Container

,

10kV Power Conversion System Container

,

2.5MW Energy Storage PCS

Rated Power: 2500kW
DC Voltage Range: 1000-1500V
Max. DC Current: 2619A
Rated AC Voltage: 10kV
Rated AC Current: 145A
Isolation: Transformer Isolation
Cooling: Air Cooling
Dimension: 5523x2400x2800mm