2.5MW 10kV Transformer Isolation Power Conversion System Container for High-Density Utility Energy Storage PCS Layouts
2.5MW 10kV PCS Container for Compact Grid-Scale Layouts
Utility-scale storage developers with tight sites face a clear trade-off: hit the target plant capacity with more lower-power PCS units, or use fewer high-power units to save land, foundations and parallel wiring. On land-constrained projects, that second option often wins.
The Voltertech 2.5MW 10kV power conversion system container answers that need. It packs 2500kW of rated output and a 1000–1500V DC input with 2619A maximum current into a single container, while sharing the same 5523×2400×2800mm footprint as the 1.25MW class — so capacity doubles without doubling the site area.
With transformer isolation, THD ≤3% at rated power and an adjustable power factor from -1 to +1, plus CAN/RS485 battery communication and Modbus RTU/TCP plus IEC 104 for dispatch, it is built for direct integration into utility SCADA and high-density grid-tied storage plants.
Key Advantages for High-Density Plant Layouts
How Unit Power Density Cuts Project Cost
Every PCS container added to a plant brings its own foundation, MV cable runs, protection equipment and commissioning work. A 10MW plant, for example, needs eight 1.25MW units but only four 2.5MW units — that is four fewer foundations, four fewer cable runs and four fewer units to maintain. For land-constrained or high-cost sites, the saving in civil works alone can be significant.
Matching Battery Blocks to a 2.5MW PCS
The 1000–1500V DC input with 2619A maximum current gives a DC-side capability of roughly 2.6MW at the upper voltage, so the PCS suits battery blocks rated near 2.4–2.5MW. Confirm the block's voltage and power before finalizing, as an oversized block under-utilizes the PCS and an undersized one limits plant output. Voltertech's 5MWh DC container is a natural pairing for this power class.
Operating Scenarios for the 2.5MW PCS Container
High-density utility storage
Multi-megawatt plants where land or foundation count is the limiting factor, such as urban-edge substations.
Large renewable co-location
Paired with utility-scale PV or wind blocks that need a single high-power conversion stage to the 10kV grid.
Industrial park storage
Compact layouts for industrial parks and commercial campuses that need maximum MW per square metre.
Core Technical Specifications
Swipe left or right to view the complete specification table.
| Parameter | Specification |
|---|---|
| DC Voltage Range | 1000–1500V |
| Rated Power (DC side) | 2500kW |
| Max. Current (DC side) | 2619A |
| Rated Output Power (AC side) | 2500kVA |
| Rated AC Voltage | 10kV |
| Rated AC Current | 145A |
| Isolation Mode | Transformer isolation |
| Max. Total Harmonic Distortion | ≤3% at rated power |
| Power Factor | -1 to +1 adjustable |
| Storage Temperature Range | -25℃ to +55℃ |
| Operating Temperature Range | -25℃ to +50℃ |
| Operating RH | 0%–95% |
| Working Altitude | ≤2000m |
| Dimension (L×W×H) | 5523×2400×2800mm |
| Net Weight | ≈15T |
| Cooling Mode | Air cooling |
| Battery Communication Interface | CAN / RS485 |
| Dispatch Communication Interface | Modbus RTU / Modbus TCP / IEC 104 |
System Integration and Project Considerations
The 2.5MW PCS container is supplied as a self-contained conversion unit for AC-side integration. The following points matter for EPCs and system integrators planning a high-density plant.
Typical High-Density Applications
Utility peak shaving
High-power PCS containers discharge stored energy during peak demand to flatten load on the medium-voltage grid with fewer units.
Renewable energy firming
Convert large PV or wind blocks into dispatchable 10kV power through paired high-capacity DC battery containers.
Industrial co-location
Land-constrained industrial parks and campuses needing maximum MW per square metre of installed equipment.
Grid frequency regulation
Rapid, adjustable power factor and low THD support frequency response in compact, high-power storage plants.
Frequently Asked Questions
Q1. Is this a complete energy storage system or just a PCS?
It is a power conversion system (PCS) container, not a battery energy storage system. It converts DC power from an external battery block into 10kV AC and must be paired with a battery container to form a complete storage plant.
Q2. How does 2.5MW compare to the 1.25MW and 1.725MW classes?
It delivers the highest power in a single container, with 2619A DC current and a 145A AC rating at 10kV. Despite the higher power, it keeps the same 5523×2400×2800mm footprint as the 1.25MW class, so capacity scales without extra land per unit.
Q3. Can multiple 2.5MW PCS containers run in parallel?
Yes. Multiple units can connect to a shared medium-voltage bus to build multi-megawatt AC-side plants, with each unit handling its own battery block. Fewer units are needed per MW than lower-power classes.
Q4. What battery voltage does it support?
The DC input range is 1000–1500V with a 2619A maximum current. Confirm the battery block's voltage and power match before finalizing.
Q5. What communication protocols are available for dispatch?
Modbus RTU, Modbus TCP and IEC 104 for grid dispatch, plus CAN/RS485 for battery BMS communication.
Q6. What cooling method does this container use?
Air cooling. Note the supplier's datasheet header lists "liquid cooling" while the cooling field states air cooling — please confirm the exact cooling configuration with our engineers before ordering.
Q7. What details do you need for a quotation?
Please provide the battery block voltage and power, total plant capacity, number of units, grid connection voltage, and project location/altitude so we can confirm the correct configuration.
Planning a High-Density Storage Plant?
Tell us your battery block size and total capacity, and we will confirm whether the 2.5MW PCS container — or a parallel arrangement — is the right fit for your project.
Share your project parameters and we will prepare a tailored quotation.
Request 2.5MW PCS Details & QuotationTransformer Isolation PCS Container
,10kV Power Conversion System Container
,2.5MW Energy Storage PCS
-
Inverter Protocol Verification Floor Standing Lithium Battery for EPCs & System Integrators in Sheltered Temperature-Controlled Sites
The Voltertech BAT-32KWH-51.2V-W is a 32kWh, 51.2V 628Ah floor-standing LiFePO4 battery featuring an IP54-rated enclosure, CAN/RS485 communication and BMS protection for solar storage projects. -
233kWh Liquid Cooled Commercial BESS for Grid-to-Off-Grid Commercial Energy Storage System
Voltertech 233kWh liquid-cooled C&I BESS with optional 100kW PCS, 20ms STS handover, grid/off-grid modes and 832V LiFePO4 battery. Designed for EPC teams planning commercial power transfer and backup load circuits. -
107kWh LiFePO4 Battery 50kVA Hybrid Solar Energy System with Integrated Battery and PCS Cabinet
107kWh 50kVA Hybrid Solar Energy System with LiFePO4 Battery The Voltertech BESS-107KWH-50KW-W is an integrated energy storage solution for hybrid solar projects requiring higher battery capacity and stable power conversion. It combines 107kWh LiFePO4 battery storage with 50kVA rated power in one ...