1.25MW 10kV Energy Storage PCS Container with Integrated Transformer for Medium-Voltage Grid Interconnection
1.25MW 10kV Energy Storage PCS Container for Medium-Voltage Interconnection
A battery container stores direct current. The grid runs on alternating current at medium or high voltage. Between them sits the power conversion system — the equipment that turns stored DC into grid-ready AC and connects the project to the network.
The Voltertech BESS-125MW-W is that conversion stage, delivered as an AC-side container. It combines a 1.25MW energy storage PCS with a transformer in one enclosure, converting DC input in the 1000–1500V range to a 10kV grid output.
Built for medium-voltage battery storage projects, it bridges DC-side battery containers to the 10kV network, with dispatch communication through IEC104 and Modbus.
Key Advantages for Grid Interconnection Projects
Where the PCS Container Sits in a Storage Project
A complete medium-voltage storage system has two sides. The DC side holds the battery containers. The AC side holds the PCS and transformer that deliver energy to the grid.
This container is the AC side. Its DC input connects to one or more battery containers, its 10kV output connects to the grid connection point, and its communication interfaces tie the whole system into grid dispatch. For an EPC contractor, it is the coordination point where battery energy becomes dispatchable grid power.
Conversion and Grid Connection Details
On the DC side, the PCS accepts a voltage range of 1000–1500V with a maximum current of 1309A, matching the high-voltage DC platforms common to modern battery containers. On the AC side, it outputs 1250kVA at 10kV with a rated current of 72.5A.
Total harmonic distortion is specified at or below 3% of rated power, and the power factor is adjustable from -1 to +1, allowing the system to support reactive power as well as active power delivery.
Operating Scenarios
Battery-to-Grid Discharge
Stored DC energy is converted to 10kV AC and delivered to the grid during discharge windows.
Grid-to-Battery Charging
Grid power is converted to DC to charge the connected battery containers during off-peak periods.
Reactive Power Support
With adjustable power factor, the system can provide reactive power support as part of the grid connection requirements.
Container Design and Site Requirements
The unit is delivered as a complete AC-side container measuring 5523 × 2400 × 2800mm and weighing approximately 6 tonnes. Cooling is by forced air, with an operating temperature range of -25°C to +50°C.
Communication covers both directions of the project: CAN/RS485 toward the battery containers, and Modbus RTU, Modbus TCP or IEC104 toward the grid operator and monitoring system.
Core Technical Specifications
Swipe left or right to view the complete specification table.
| Parameter | Specification |
|---|---|
| Model | BESS-125MW-W |
| System Type | AC-Side Energy Storage PCS Container (with Transformer) |
| DC Voltage Range | 1000V – 1500V |
| DC-Side Rated Power | 1250kW |
| DC-Side Maximum Current | 1309A |
| AC-Side Rated Output Power | 1250kVA |
| Rated AC Voltage | 10kV |
| Rated AC Current | 72.5A |
| Isolation Mode | Transformer Isolation |
| Max. Total Harmonic Distortion | ≤ 3% of Rated Power |
| Power Factor | -1 to +1 (Adjustable) |
| Battery Communication Interface | CAN / RS485 |
| Dispatch Communication Interface | Modbus RTU / TCP / IEC104 |
| Cooling Mode | Air Cooling |
| Operating Temperature | -25°C to +50°C |
| Storage Temperature | -25°C to +55°C |
| Operating Humidity | 0% – 95% |
| Working Altitude | ≤ 2000m |
| Dimensions (L × W × H) | 5523 × 2400 × 2800mm |
| Net Weight | Approx. 6 T |
System Planning and Integration
Typical Medium-Voltage Applications
Grid-Scale Battery Projects
The AC-side conversion stage for multi-MWh battery container installations connecting to a 10kV grid.
Industrial Peak-Valley Storage
Medium-voltage PCS for industrial sites buying energy off-peak and discharging during peak tariff periods.
Renewable Co-Located Storage
Conversion and grid connection for storage paired with solar or wind generation at the medium-voltage level.
EPC and System Integration
A standardized AC-side block for contractors delivering repeatable medium-voltage storage projects.
Frequently Asked Questions
Q1. Is this a complete energy storage system?
No. This is the AC-side power conversion and grid-connection container. It pairs with DC-side battery containers to form a complete storage installation. The PCS sets power, the batteries set stored energy.
Q2. What battery containers does this PCS work with?
Battery containers operating within a DC voltage range of 1000–1500V, with CAN or RS485 communication. The exact matching should be confirmed against the battery specifications during system design.
Q3. Why is the transformer included in the container?
The step-up transformer is integrated so the PCS can deliver directly at 10kV medium voltage. This reduces separate transformer equipment and the site wiring between conversion and grid connection.
Q4. What does "power factor -1 to +1" mean?
It means the system can operate across leading and lagging power factors, supporting reactive power as well as active power. This helps meet grid connection and power quality requirements.
Q5. How does the system communicate with the grid operator?
Through Modbus RTU, Modbus TCP or IEC104 dispatch interfaces, allowing the operator to schedule charging and discharging and monitor the system remotely.
Q6. Can several PCS containers be combined?
Yes. Multiple PCS containers can be deployed alongside the corresponding battery capacity to build larger medium-voltage installations, coordinated at the project level.
Q7. What information is needed for a quotation?
Please provide the destination country, grid voltage and connection requirements, the battery containers to be connected and their DC voltage, required power in MW, dispatch communication requirements, and the quantity. A single-line diagram helps with configuration.
Connecting Battery Containers to the Medium-Voltage Grid?
Voltertech supplies AC-side PCS containers for EPC contractors, integrators and medium-voltage storage projects. Share your battery configuration and grid connection requirements for system matching and quotation.
OEM options are available for regional partners and project deployments.
Request 1.25MW PCS Container Details & Quotation1.25MW Energy Storage PCS Container
,10kV Power Conversion System Container
,Transformer Integrated PCS Container
-
16kWh IP65 Floor Standing Lithium Battery with Lifting Casters for Solar Storage
16.08kWh 51.2V 314Ah floor-standing LiFePO4 battery with IP65 enclosure, heavy-duty lifting casters, touchscreen and CAN/RS485 communication. Supports up to 15 units in parallel for compatible solar energy storage systems. -
2.5MW 10kV Transformer-Isolated Power Conversion System for Hybrid Solar Energy Storage
2.5MW 10kV Hybrid Solar Energy Storage Power Conversion System The Voltertech BESS-25MW-W is a 2.5MW transformer-isolated power conversion unit for MW-scale hybrid solar and battery storage projects. It connects compatible 1000–1500V DC battery systems to a 10kV medium-voltage AC network and ... -
233kWh 100kW Liquid Cooled Commercial Battery Energy Storage Cabinet for C&I Projects
100kW 233kWh Liquid Cooling C&I Energy Storage System The 100kW 233kWh Liquid Cooling C&I Energy Storage System combines a 233kWh LiFePO4 battery with a 100kW rated PCS for commercial and industrial energy storage projects where energy duration is as important as power capacity. The battery section ...