233kWh Commercial Energy Storage System with Diesel Generator Linkage and 20ms STS Transfer for Remote Off-Grid Sites

Product Summary
233kWh off-grid battery storage for remote sites and diesel displacement. 100kW on/off-grid PCS, 156kW PV input, 20ms transfer, diesel generator linkage, liquid cooling, 3-unit parallel. For mines, camps, islands, telecom sites. OEM available.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: IEC62477-1 , IEC61000-6/2/4 , UN3536
Model Number: BESS-233KWH-100KW-W-4
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

233kWh Off-Grid Battery Storage With Diesel Generator Linkage

Remote sites run on diesel. Mines, construction camps, islands and telecom stations rely on generators that burn fuel every hour, need regular delivery, and cost far more per kilowatt-hour than grid power ever would.

The Voltertech BESS-233KWH-100KW-W is a hybrid storage system built to cut that dependence. It combines 233kWh of LiFePO4 storage, a 100kW on/off-grid PCS, optional 156kW solar input and diesel generator linkage in one liquid-cooled cabinet.

With 20ms transfer, three-unit parallel capability and operation from -20°C to +60°C, it is designed for sites where reliable power means keeping diesel in reserve rather than running it continuously.

Key Advantages for Remote and Off-Grid Power

100kW On/Off-Grid PCS Delivers rated power whether a utility grid is present or not, with 220/230/380/400V off-grid output options and 100% load unbalance tolerance.
Diesel Generator Linkage Coordinates storage with an existing generator so the set runs less often, mainly to recharge the battery rather than supply loads directly.
156kW Optional PV Input Two solar channels with a 180–800V MPPT range let the site generate its own power, further reducing fuel consumption.

The Real Cost of Diesel at Remote Sites

Diesel generation costs more than the price of fuel. There is the delivery to a remote location, the storage on site, the engine maintenance and the noise and emissions. For many operations, the generator is the single largest running cost after labour.

Storage changes how the generator is used. Instead of running all day to serve a varying load, the generator can charge the battery during a short, efficient window. The battery then supplies the site from stored energy, keeping the engine off for most of the day.

Planning Note: Storage does not produce energy — it shifts when energy is used. The savings come from running the generator at its most efficient point and avoiding hours of low-load diesel operation.

How Solar, Battery and Diesel Work Together

Each source has a defined role. Solar provides the lowest-cost energy when the sun is up. The battery stores that energy and releases it whenever demand rises. The generator acts as the last resort, available to recharge the bank when solar and stored energy are not enough.

The system coordinates these sources automatically. A 20ms transfer keeps sensitive equipment supplied through source changes, and the generator linkage function manages when the diesel set starts and stops.

Operating Scenarios

Daytime Solar and Battery Supply

Solar generation serves site loads and charges the battery during the day, while the generator stays off.

Evening and Night Battery Operation

Stored energy covers the site through the night, replacing generator runtime during the highest-cost hours.

Generator Recharge and Backup

When solar is insufficient, the generator runs briefly to recharge the battery, then stops — keeping fuel use to a minimum.

Grid Connection Where Available

Where a utility connection exists, the same cabinet supports on-grid operation at AC 380/400V with self-consumption and peak management.

Sizing Storage to Cut Diesel Runtime

Start with the site's daily energy consumption in kWh and the hours the generator currently runs. A storage system sized to cover the evening and overnight period removes the largest block of that runtime at once.

For remote sites, it is often more economical to separate essential loads from optional ones. Keeping communications, lighting, refrigeration and control systems on stored power — while scheduling heavy work into daylight hours — reduces both battery size and fuel use.

Core Technical Specifications

Swipe left or right to view the complete specification table.

Parameter Specification
Model BESS-233KWH-100KW-W
System Type Liquid-Cooled Hybrid Off-Grid Storage System
Battery Chemistry LiFePO4
Total Capacity 233kWh
Nominal Capacity (Cell) 280Ah
Nominal Voltage 832V
Operating Voltage Range 702V – 936V
Nominal Charge / Discharge Current 140A
PCS Rated Output (On-Grid / Off-Grid) 100kW
On-Grid Voltage AC 380/400V, 50/60Hz
Off-Grid Voltage 220/230/380/400V
Rated AC Current (On-Grid) 167A / 159A
Degree of Unbalance 100%
Max. PV Input Power (2 Channels) 156kW (Optional)
MPPT Voltage Range 180V – 800V
STS Transfer Time 20ms
Diesel Generator Function Generator linkage supported
Maximum Efficiency 98%
Cooling Mode Liquid Cooling
Cycle Life / Calendar Life 8000 Cycles / 15 Years
Operating Temperature -20°C to +60°C
Enclosure Protection IP54
Communication LAN / RS485 / CAN
Dimensions (L × W × H) 1385 × 910 × 2203mm
Net Weight Approx. 2.3 T

System Integration and Site Considerations

Load Profile
Record daily energy use and current generator hours. This defines the storage capacity that removes the most diesel runtime.
Generator Coordination
Confirm the generator's rating and control interface so the linkage function can manage start and stop behaviour correctly.
Solar Input
Where PV is planned, verify string voltage against the 180–800V MPPT range. Solar input is an option, not a requirement.
Site Conditions
The cabinet measures 1385 × 910 × 2203mm and weighs approximately 2.3 tonnes. Allow clearance for liquid-cooling service access and protection from standing water.
System Expansion
Up to 3 units can operate in parallel for larger sites or longer autonomy, coordinated through the communication interfaces.

Typical Remote and Off-Grid Applications

Mines and Quarries

Reducing generator fuel consumption at sites where diesel delivery is expensive and logistically difficult.

Construction and Remote Camps

Power for site offices, lighting, refrigeration and accommodation, with generators kept as backup rather than baseload.

Islands and Remote Communities

Hybrid solar-plus-storage systems replacing part of a diesel mini-grid, lowering fuel dependence and operating cost.

Telecom Towers and Remote Infrastructure

Continuity for communication equipment at sites with unreliable or absent grid supply, reducing generator service visits.

Frequently Asked Questions

Q1. Can this system replace a diesel generator completely?

It can remove most generator runtime where solar and battery capacity are sized to the site's daily consumption. The generator is usually retained as backup for extended bad weather or unusual loads, rather than eliminated entirely.

Q2. What does the 20ms transfer time mean for my site?

It is how quickly the system switches between power sources during an interruption, keeping sensitive equipment supplied through the changeover. Site protection coordination should still be reviewed by the electrical contractor.

Q3. How much solar can be connected to the cabinet?

Up to 156kW across two PV channels, with an MPPT operating range of 180–800V. Solar input is optional — the system also works with battery and generator only.

Q4. Can it operate without any utility grid at all?

Yes. The PCS supports off-grid output at 220/230/380/400V with 100kW rated power and 100% load unbalance tolerance, suited to fully remote sites.

Q5. How does the diesel generator linkage work?

The system coordinates with the generator so it starts to recharge the battery when needed and stops when storage is restored. This keeps the engine running at efficient load instead of supplying fluctuating site demand directly.

Q6. Can several cabinets be installed at one site?

Yes. Up to 3 units can operate in parallel for higher capacity or longer autonomy, coordinated through the LAN, RS485 and CAN interfaces.

Q7. What information is needed for a remote site quotation?

Please provide the destination country, daily energy consumption in kWh, current generator runtime and fuel use, planned solar capacity if any, site voltage requirements and the number of cabinets needed. Site photos help with planning.

Planning Power for a Remote Site?

Voltertech supplies hybrid off-grid storage systems for remote industrial sites, EPC contractors and project developers looking to reduce diesel dependence. Share your energy consumption and generator data for system sizing and quotation.

OEM options are available for regional partners and repeat project deployments.

Request 233kWh Off-Grid Storage Details & Quotation
Product Details
Highlight:

Diesel Generator Linkage Battery Energy Storage System

,

20ms STS Transfer Commercial Energy Storage System

,

233kWh Capacity Commercial Battery Storage

Application: Off-Grid / Diesel Replacement
Target Buyers: EPC, Distributors, Site Operators
Site Types: Mine / Camp / Island / Telecom
PCS Output: 100kW On/Off-Grid
PV Input: 156kW Optional / 3 MPPT Range
Transfer Time: 20ms STS
Generator: Diesel Linkage Supported
Supply Type: OEM / Project Support