16kW Hybrid Solar Inverter with 3 MPPT and 21.8kW PV Input for Farm and Off-Grid Power

Product Summary
16kW hybrid solar inverter for farm and off-grid power. 16000W output, 21.8kW PV input, 3 MPPT trackers, 250A max charging, 100A passthrough, 48V LiFePO4 compatible, IP65. For irrigation pumps, cold storage and rural sites. OEM/ODM available.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: MSDS
Model Number: INV-16KW-51.2V-W-4
Trading Properties
Minimum Order Quantity: 2 Units
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Sets per Month
Product Description

16kW Hybrid Solar Inverter for Farm and Off-Grid Power

Farms and rural facilities face a different energy problem from urban buildings. Grid connections may be weak, unstable or simply unavailable, while essential equipment — irrigation pumps, cold rooms, workshops and farm offices — still needs reliable power every day. A failed pump during a dry week or a warm cold room after harvest can cost far more than the power system itself.

The Voltertech INV-16KW-51.2V-W is a 16kW single-phase hybrid solar inverter developed for farm and off-grid power applications. It provides 16,000W rated AC output, supports up to 21.8kW of photovoltaic input through three MPPT trackers, and delivers up to 250A of battery charging current with a 100A AC passthrough rating.

Operating on a 48V-class battery platform, the inverter integrates with compatible LiFePO4 storage systems. Its IP65 enclosure, Wi-Fi monitoring and parallel capability of up to 6 units support installations ranging from single farm sites to larger rural energy projects.

Key Advantages for Farm and Rural Projects

16kW AC Output 16,000W pure sine wave output for combined farm loads such as irrigation pumps, cold storage and workshop equipment, subject to verified starting requirements.
3 MPPT Trackers, 21.8kW PV Three independent solar inputs accept up to 21,800W of PV across separate roofs or ground-mounted arrays with different orientations.
250A Charging + Generator Support Up to 250A charging current and dual independent AC inputs allow solar, grid and generator sources to be coordinated in one system.

Sizing Solar Power for Real Farm Loads

Farm electrical demand is usually dominated by motor-driven equipment. An irrigation pump may run for hours at a steady load, but its starting current can reach several times the running value. Cold rooms and refrigeration add compressor loads that cycle throughout the day and night.

The INV-16KW-51.2V-W provides 16kW rated output with a nominal output current of 69.6A. For farm projects, the key design step is listing every motor and compressor, confirming starting current or soft-start arrangements, and checking which loads must operate simultaneously. A system sized only from running watts is a common cause of tripping and early failures in agricultural installations.

Pump Sizing Note: A 16kW rating does not automatically mean any 16kW pump can be started. Direct-on-line motors may require several times their rated power at startup. Confirm the pump's starting method and current before finalizing the inverter selection.

Using Three MPPT Trackers Across Farm Buildings

Solar panels on a farm rarely sit on a single roof. The pump house may face one direction, the cold room another, and a ground-mounted array may occupy open land nearby. With a single-MPPT inverter, these arrays must be combined or redesigned around one orientation.

The three MPPT trackers on the INV-16KW-51.2V-W accept separate PV strings with different orientations or shading conditions, with input currents of 18A + 18A + 36A and an MPPT operating range of 50–450VDC. This gives installers practical freedom to use the roofs and land already available on the farm, rather than redesigning the site around the inverter.

Farm Operating Scenarios

Daytime Solar Irrigation and Farm Loads

Solar generation supplies pumps and daytime equipment directly while charging the battery, aligning irrigation schedules with peak sunlight hours.

Battery Backup for Cold Storage and Essential Loads

Stored energy keeps refrigeration, lighting and essential circuits running through the night or during grid outages.

Hybrid Solar, Grid and Generator Operation

Dual independent AC inputs allow grid and generator sources to be integrated with solar and battery storage, providing layered backup for remote sites.

Battery Selection for a 16kW Farm System

The inverter operates on a nominal 48VDC battery platform with up to 250A charging current. Compatible LiFePO4 battery systems should match the voltage range, charging limits and CAN or RS485 communication requirements of the inverter.

For farm projects, battery sizing depends on which loads must run after sunset. Cold storage and essential circuits typically justify storage first, while irrigation can often be scheduled into daylight hours to reduce battery demand. Many farm installations in this power class start from 30–40kWh of storage, with additional battery units added as the operation grows, within BMS and protection limits.

Core Technical Specifications

Swipe left or right to view the complete specification table.

Parameter Specification
Model INV-16KW-51.2V-W
Inverter Type Single-Phase Hybrid Solar Inverter
Rated AC Output Power 16,000W
Nominal AC Output Voltage 220 / 230 / 240VAC
Nominal AC Output Current 69.6A
Output Waveform Pure Sine Wave
Maximum PV Input Power 21,800W
Maximum PV Input Voltage 520VDC
MPPT Operating Voltage Range 50–450VDC
Number of MPPT Trackers 3
PV Input Current 18A + 18A + 36A
Nominal Battery Voltage 48VDC
Maximum Charging Current (Solar / AC / Combined) 250A
Maximum Charging Power 14,000W (56V)
Maximum AC Input Current 100A (Passthrough)
Maximum Conversion Efficiency (DC/AC) 97%
Communication RS485 / CAN / Wi-Fi / Dry Contact
Parallel Operation Up to 6 Units (Single-Phase) / 3 Units (Three-Phase)
Protection Rating IP65
Operating Temperature -10°C to +50°C
Product Dimensions (D × W × H) 637.5 × 491 × 300.5mm
Net Weight 50kg

System Integration and Project Considerations

For installers and distributors serving agricultural customers, a dependable farm power system depends on matching the inverter, PV layout, battery bank and motor loads to the actual working routine of the farm.

Load Assessment
List all pumps, compressors and workshop equipment with running and starting currents. Identify which loads can be scheduled into daylight hours.
PV Layout
Assign PV strings across the three MPPT trackers according to roof orientation, ground-mount location and shading conditions on the site.
Battery Compatibility
Confirm battery charge-current acceptance and BMS communication with the inverter before ordering. Size storage around overnight essential loads.
Generator Integration
Use the independent AC inputs to coordinate grid and generator backup where the farm already operates a diesel generator.
System Expansion
Up to 6 units can operate in parallel for larger single-phase sites, or 3 units in an approved three-phase configuration.

Typical Farm and Off-Grid Applications

Irrigation and Water Pumping

Solar-powered pumping for irrigation, livestock watering and water transfer, with daytime scheduling to make direct use of solar generation. Pump starting requirements must be verified.

Cold Storage and Produce Handling

Backup for cold rooms, refrigeration and packing equipment where temperature interruptions directly cause product losses.

Farm Workshops and Offices

Power for tools, machinery, computers and lighting within the inverter's rating, integrated with the same solar and battery system serving the rest of the farm.

Rural Sites and Off-Grid Facilities

Complete solar-plus-storage systems for remote homes, estates, field stations and rural facilities where grid power is unavailable or unreliable.

Frequently Asked Questions

Q1. Can a 16kW inverter run an irrigation pump?

It can support pumps whose running and starting requirements fall within the inverter's capability. The critical check is starting current: direct-on-line motors may need several times their rated power at startup. Share the pump nameplate or starting method with your supplier before confirming the selection.

Q2. What is the advantage of three MPPT trackers on a farm?

Farm solar arrays are often spread across different roofs or ground locations with different orientations and shading. Three independent MPPT inputs allow these arrays to be used efficiently without forcing every panel into the same electrical configuration.

Q3. How much battery capacity does a farm system need?

It depends on which loads must operate after sunset. Farms that schedule irrigation into daylight hours mainly need storage for cold rooms and essential night loads. Projects in this power class commonly start from 30–40kWh and expand as needed.

Q4. Can this inverter work with a diesel generator?

The series provides two independent AC inputs, allowing grid and generator sources to be integrated with solar and battery storage. The exact wiring and control configuration should be confirmed during system design.

Q5. What is the difference between the 12kW and 16kW models?

The 16kW model offers higher AC output (16,000W vs 12,000W), three MPPT trackers instead of two, a larger PV input limit (21.8kW vs 16.2kW) and a 100A passthrough rating. It is typically selected for farms and larger sites with multiple buildings and motor-driven loads.

Q6. Can this inverter supply three-phase equipment?

A single unit is single-phase and cannot directly power three-phase loads. An approved three-unit three-phase configuration is available for suitable projects, subject to verification against current manufacturer documentation and site requirements.

Q7. What information is needed for a farm power quotation?

Please provide the destination country, equipment list with power ratings (especially pumps and compressors), planned PV array locations, intended battery capacity or backup hours, grid and generator availability, and required quantity. Site photos or a simple layout sketch also help with system design.

Planning a Solar Power System for a Farm Project?

Voltertech supplies hybrid solar inverters and compatible LiFePO4 battery systems for agricultural and off-grid projects. Share your equipment list, site layout and backup requirements for system matching and quotation.

OEM and ODM options are available for distributors and regional project partners.

Request 16kW Inverter Details & Quotation
Product Details
Highlight:

Farm and Off-Grid Power Hybrid Solar Inverter

,

3 MPPT Hybrid Solar Inverter

,

21.8kW PV Input Solar Inverter

Application: Farm & Off-Grid Power
Target Buyers: Distributors, Installers, EPC
Farm Loads: Irrigation / Cold Storage
Battery Type: 48V LiFePO4 Compatible
PV Input: 21.8kW Max / 3 MPPT
Charging Current: 250A Max
Parallel: Up To 6 Units
Supply Type: OEM / ODM / Wholesale

Customer Service

Related Products
Send An Inquiry