6kW Solar Inverter For 48V Battery Systems With 120A PV AC Charging
6kW Solar Inverter for 48V Battery Systems with 120A PV and AC Charging
Flexible 48V Battery Integration for Solar Backup Systems
This 6kW solar inverter is designed around a 48V battery platform and supports compatible lithium and lead-acid battery systems. It integrates photovoltaic charging, AC charging, pure sine wave output and energy-management interfaces in one unit.
The formal specification lists a maximum photovoltaic charge current of 120A and a maximum AC charge current of 120A. When photovoltaic and AC charging are used together, the listed combined maximum remains 120A rather than increasing to 240A.
This version is positioned for battery distributors, solar installers and system integrators requiring a higher-output inverter for 48V battery banks, with CT/Meter access, dry-contact control and optional WiFi monitoring.
Battery Compatibility and Charging Functions
48V Battery Platform
The inverter operates with a nominal 48Vdc battery bank and requires correctly configured DC cabling and protection equipment.
Lithium and Lead-Acid Support
Compatible lithium or lead-acid batteries can be selected according to the project’s required capacity, chemistry and charging settings.
120A Photovoltaic Charging
The MPPT charger can provide up to the listed 120A limit when sufficient solar power is available and the battery accepts the configured current.
120A AC Charging
Compatible AC input can supplement photovoltaic charging when solar production is insufficient or faster battery recovery is required.
Battery Capacity and Charging-Current Planning
The maximum inverter charging current should not automatically be applied to every battery. The selected value must remain within the battery manufacturer’s permitted charge rate, BMS or protection limit, cable capacity and DC protection rating.
The formal parameter table lists a floating-charge voltage of 56V and an overcharge-protection voltage of 60V. Final settings must match the selected battery chemistry and supplier instructions.
Battery capacity determines expected operating duration, while the inverter rating determines the maximum continuous load. A larger battery reserve can extend backup time but does not increase the 6kW continuous output.
The maximum combined photovoltaic and AC charging current is listed as 120A. Charging priorities must be coordinated so that the total configured current does not exceed this value.
Battery and Charging Specifications
| Battery Voltage Platform | 48Vdc |
| Battery Compatibility | Lithium and Lead - Acid Batteries |
| Battery Charging Voltages | 56V Floating Charge / 60V Overcharge Protection |
| Maximum PV Charge Current | 120A |
| Maximum AC Charge Current | 120A |
| Maximum Combined Charge Current | 120A PV + AC Combined |
| Battery-Mode Performance | 6kW Continuous / 12kVA Surge / Up to 93% Efficiency at 48Vdc |
| Monitoring and Control | LCD / RS485 / USB / Dry Contact / CT/Meter / Optional WiFi |
| Environmental and Physical Data | IP21 / -10°C to 50°C / 392.5 × 325 × 130mm / 8.5kg |
Battery type, capacity, charging voltage, current limit, DC cabling and protection devices must be confirmed before commissioning. This page does not replace the battery manufacturer’s technical instructions.
48V Battery Solar Inverter FAQ
Does the inverter support lithium and lead-acid batteries?
Yes. Both battery types are listed, but the charging voltages and current settings must match the selected battery system.
Does 120A PV plus 120A AC provide 240A charging?
No. The formal table lists a maximum combined photovoltaic and AC charging current of 120A.
Can every 48V battery accept 120A charging?
No. The permitted current depends on battery capacity, chemistry, BMS or protection rating, cable size and DC protection equipment.
What are the listed battery charging voltages?
The specification lists 56V for floating charge and 60V for overcharge protection. Final settings must follow the battery supplier’s instructions.
What is the purpose of the CT/Meter interface?
The interface can support compatible energy measurement and system-control functions when the required external devices and settings are used.
48V Battery Inverter Project Support
This solar inverter is suitable for battery distributors, solar installers and system integrators requiring a 48V platform with high-current photovoltaic and AC charging.
Selecting a compatible 48V battery bank and charging-current configuration?
6kW Solar Inverter 120A
,48V Battery Solar Inverter
-
10.24kWh 51.2V Wall Mounted LiFePO4 Battery With 200A Current Capability
10.24kWh 51.2V Wall Mounted LiFePO4 Battery with 200A Current Capability This 10.24kWh wall mounted LiFePO4 battery provides a higher-capacity storage option for residential solar systems, office backup, communication equipment, security systems and other projects requiring a larger energy reserve ... -
1000W 2009Wh Energy Storage System Wall Mounted For Indoor Backup
This wall mounted all in one energy storage system integrates a 2009.6Wh LiFePO4 battery, 1000W pure sine wave inverter, BMS and MPPT controller in a 90mm slim enclosure. It supports indoor backup, solar charging and compact installation in homes and small technical spaces. -
Stackable Modular LiFePO4 Energy Storage Battery All In One 15.36kWh 3.6kW
15.36kWh 3.6kW All in One Energy Storage System with Modular LiFePO4 Stack This all in one energy storage system combines a 15.36kWh LiFePO4 battery stack with a 3.6kW pure sine wave inverter and MPPT charging. It is the largest battery configuration in this series and is designed for projects where ...