3.6kW 24V Solar Single Phase Inverter With 5kW MPPT 5.7kVA Surge

Product Summary
Single - Phase 3.6kW 24V Solar Inverter with 5kW MPPT and 5.7kVA Surge High - PV-Input Inverter for Residential and Small Business Loads This single-phase 3.6kW 24V solar inverter combines pure sine wave AC output, a wide-range MPPT solar charger, utility input and battery charging in one compact ...
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: MSDS
Model Number: INV-3.6KW-24V-Q
Trading Properties
Minimum Order Quantity: 2 Units
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Sets per Month
Product Description

Single - Phase 3.6kW 24V Solar Inverter with 5kW MPPT and 5.7kVA Surge

High - PV-Input Inverter for Residential and Small Business Loads

This single-phase 3.6kW 24V solar inverter combines pure sine wave AC output, a wide-range MPPT solar charger, utility input and battery charging in one compact power-conversion platform.

The inverter provides 3.6kW of continuous output and 5.7kVA of short-duration surge capacity. It can support compatible lighting, refrigeration, computers, communication equipment, televisions, fans and selected pumps or air conditioners after their running and startup requirements have been checked.

Its built-in MPPT charger supports up to 5kW of photovoltaic input, allowing the solar array to be sized above the continuous AC output when daytime loads and battery charging are considered together.

Solar Power and Load Management

5kW Photovoltaic Input

The MPPT charger accepts up to 5000W of solar input with a listed maximum photovoltaic current of 18A.

Wide MPPT Operating Range

The 40–450Vdc operating window provides flexibility when designing suitable photovoltaic strings for different panel specifications.

5.7kVA Surge Headroom

Short-duration surge capacity helps accommodate compatible motor and compressor starting loads without changing the 3.6kW continuous rating.

Multiple Energy Sources

Solar, battery, compatible utility input and generator support can be coordinated according to the selected operating settings.

PV String and Appliance Sizing

Photovoltaic string voltage must remain within the 40–450Vdc MPPT operating range, while total open-circuit voltage must stay below the 500Vdc maximum. Cold-weather open-circuit voltage should be calculated before installation.

The combined continuous AC load should remain within 3.6kW. Refrigerators, pumps, compressors and air conditioners require an additional startup assessment because their initial demand may be higher than their normal running power.

Battery capacity determines operating duration and must be selected separately from inverter output. A higher-capacity battery can extend runtime, but it does not increase the inverter’s 3.6kW continuous output limit.

The inverter supports solar self-consumption, battery backup and compatible utility charging. This page does not claim electricity selling or power export to the grid.

Electrical and Installation Specifications

AC Output 3.6kW / 208, 220, 230 or 240Vac / PF 1.0
Surge Power 5.7kVA
AC Input Range 90–280Vac Normal Mode / 170–280Vac UPS Mode
Transfer and Waveform 10ms / Pure Sine Wave
Maximum PV Input 5000W / 18A
PV Voltage Limits 40–450Vdc MPPT / 500Vdc Maximum Open-Circuit Voltage
Battery-Mode Efficiency Up to 92.7% at 24Vdc
Communication and Monitoring LCD / RS485 / RS232 / USB / Optional WiFi
Size and Environment 289 × 420 × 100mm / 6.3kg / IP21 / -10°C to 50°C

3.6kW Solar Inverter FAQ

Can the inverter continuously supply 5.7kW?

No. Continuous output is 3.6kW. The 5.7kVA specification represents short-duration surge capacity for compatible starting loads.

Can a 5kW solar array be connected to a 3.6kW inverter?

The solar charger is rated for up to 5kW of photovoltaic input, subject to the 18A current limit and specified voltage limits.

Can it support a pump or air conditioner?

Compatible equipment may be supported when its running power, startup demand and combined system load remain within the inverter limits.

Does the inverter support generator input?

Generator operation is supported when the generator provides compatible voltage, frequency and sufficient capacity for active loads and charging.

Where should the inverter be installed?

The IP21 unit should be installed in a dry, protected and ventilated technical area with sufficient cable and maintenance clearance.

Solar Inverter Project Support

This solar inverter is suitable for distributors, installers and system integrators serving residential solar, small business backup and generator-assisted power projects.

Planning a 3.6kW solar system with up to 5kW of photovoltaic input?

Request a Solar Inverter Configuration

Product Details
Highlight:

3.6kW Solar Single Phase Inverter

,

24V Solar Single Phase Inverter

,

MPPT 24V Solar Inverter

Continuous AC Output: 3.6kW Pure Sine Wave
Starting Load Capacity: 5.7kVA Surge Power
Solar Input Capacity: Up To 5kW / 18A
MPPT Voltage Window: 40–450Vdc
Maximum PV Open-Circuit Voltage: 500Vdc
Battery Voltage Platform: 24V Lithium Or Lead-Acid
Source Transfer Response: 10ms
Monitoring And Communication: LCD / RS485 / RS232 / USB / Optional WiFi

Customer Service