57.6kWh Air-Cooled Commercial Energy Storage System for Cold Storage Battery Energy Storage System
57.6kWh Battery Storage for Cold Storage and Refrigeration
For a cold storage operator, a power interruption is measured in product, not inconvenience. A few hours without cooling can spoil a full room of produce, seafood or vaccines.
Refrigeration also carries one of the highest daytime electricity loads on a commercial site. Compressors, condensers and fans work hardest when the sun is strongest — and that is exactly when electricity is most expensive in many markets.
The Voltertech BESS-57KWH-25KW-W is a battery storage system sized for cold rooms and cold chain facilities. It combines 57.6kWh of LiFePO4 storage with a 25kVA on/off-grid PCS in an air-cooled cabinet, with solar input available as an option.
Key Advantages for Cold Chain Projects
Matching Cooling Loads to Solar Hours
Cold rooms have a useful characteristic: their largest electrical load usually falls between late morning and late afternoon. Ambient temperature is highest, door openings are frequent, and compressors run longest.
A solar array produces on the same curve. With optional PV connected, the installation can supply daytime cooling from the panels and charge the battery at the same time, then draw on stored energy after sunset.
Planning Hold-Over Time
Hold-over time is the number of hours a cold room can stay within its temperature band without grid power. It depends on the compressor duty cycle, insulation, door traffic and ambient conditions.
As a working reference in this capacity class, a 57.6kWh system supporting a reduced essential cooling load can bridge a multi-hour outage. Installers should still confirm the actual figure from the site's compressor data — a system sized from guesswork is the most common cause of disappointing cold chain projects.
Operating Scenarios
Solar-Led Daytime Cooling
PV generation supplies compressors during peak cooling hours while charging the battery from surplus solar.
Night and Outage Hold-Over
Stored energy keeps essential refrigeration running after sunset or during grid interruptions.
Peak and Tariff Management
The same cabinet can shave short demand peaks during normal operation, improving project economics between outages.
Air Cooling and Installation
This cabinet uses air cooling rather than a liquid loop. For a mid-sized system, that keeps the design simple: no coolant circuit, fewer service items, and maintenance that a local refrigeration or electrical contractor can handle.
The enclosure is rated IP54 with an operating range of -20°C to +50°C. The unit measures 1100 × 1000 × 2100mm and weighs approximately 1050kg, so it suits a plant room, service yard or covered external position with adequate ventilation clearance.
Core Technical Specifications
Swipe left or right to view the complete specification table.
| Parameter | Specification |
|---|---|
| Model | BESS-57KWH-25KW-W |
| System Type | Air-Cooled Commercial Battery Storage System |
| Battery Chemistry | LiFePO4 |
| Total Capacity | 57.6kWh |
| Nominal Capacity (Cell) | 100Ah |
| Nominal Voltage | 576V |
| Operating Voltage Range | 468V – 648V |
| Nominal Charge / Discharge Current | 50A |
| PCS Rated Output (On-Grid / Off-Grid) | 25kVA |
| Max. Output Power (Off-Grid) | 27.5kVA |
| Rated AC Voltage | AC 230/400V, 50/60Hz |
| Rated AC Current (On-Grid) | 36.2A |
| AC Voltage Harmonic | < 3% |
| Max. PV Input Power (2 Channels) | 15kW + 15kW (Optional) |
| Max. PV Input Current (2 Channels) | 25A + 25A |
| Maximum PV Voltage | 850V |
| Starting Voltage | 250V |
| MPPT Voltage Range | 200V – 800V |
| Cooling Mode | Air Cooling |
| Cycle Life / Calendar Life | 6000 Cycles / 15 Years |
| Operating Temperature | -20°C to +50°C |
| Storage Temperature | -30°C to +60°C |
| Operating Humidity | 5% – 95% |
| Working Altitude | ≤ 2000m |
| Enclosure Protection | IP54 |
| Communication | LAN / RS485 / CAN |
| Dimensions (L × W × H) | 1100 × 1000 × 2100mm |
| Net Weight | Approx. 1050kg |
System Planning and Integration
Typical Cold Chain Applications
Produce and Agricultural Cold Rooms
Post-harvest storage for fruit, vegetables and dairy, where daytime cooling demand aligns well with solar generation.
Seafood and Meat Processing
Cold rooms and freezers where a temperature excursion causes immediate and visible product loss.
Pharmaceutical and Vaccine Storage
Temperature-controlled facilities requiring dependable hold-over time and monitoring capability.
Distribution and Cold Chain Hubs
Logistics depots and wholesale markets combining refrigeration with high daytime electricity costs.
Frequently Asked Questions
Q1. How long can a 57.6kWh system keep a cold room running?
It depends on the essential cooling load in kW and the required hold-over hours. A reduced essential-load setup can bridge a multi-hour outage; a full compressor load uses the stored energy much faster. The site's compressor data should drive the calculation.
Q2. Can a 25kVA PCS handle compressor starting currents?
The PCS provides 25kVA rated output with up to 27.5kVA maximum off-grid output. Compressor starting method and starting current must still be verified during design — direct-on-line motors can demand several times their running current.
Q3. Why add solar to a cold storage project?
Refrigeration demand is usually highest during the middle of the day, which is when solar generation peaks. PV can supply that cooling load directly and charge the battery for the evening, reducing both grid purchases and generator runtime.
Q4. Is solar input required, or can the system run on grid and battery only?
PV input is optional. The system also operates with grid charging and battery discharge only, which suits sites where a solar array is planned for a later phase.
Q5. Why air cooling for a cold storage application?
At this capacity, forced air is sufficient for the heat load and avoids the coolant circuit and service items of a liquid system. It keeps maintenance straightforward for local contractors.
Q6. Can the system also provide general backup for the site?
Yes. Beyond essential refrigeration circuits, the cabinet can supply selected site loads during an outage. Backup allocation should be planned separately from the cooling hold-over requirement.
Q7. What information is needed for a cold storage quotation?
Please provide the destination country, cold room temperature range, compressor and condenser list with power ratings, required hold-over hours, planned solar capacity if any, site voltage, and the required quantity.
Planning Storage for a Cold Chain Project?
Voltertech supplies air-cooled commercial battery storage for refrigeration integrators, EPC contractors and cold chain distributors. Share your cooling load list and hold-over requirement for system sizing and quotation.
OEM and ODM options are available for bulk orders and regional distribution programs.
Request 57.6kWh BESS Details & Quotation57.6kWh Commercial Energy Storage System
,Air-Cooled Battery Energy Storage System
,Cold Storage Commercial Battery Storage
-
48kWh Stackable Floor Standing Lithium Battery with Up to 15 Units Parallel for Solar Energy Storage
Voltertech BAT-48KWH-51.2V-W offers 48.23kWh nominal storage in a floor-standing 51.2V 942Ah LiFePO4 battery, with IP54 protection and CAN/RS485 communication for compatible farm, workshop and distributed solar installations. -
57.6kWh 25kVA Air Cooling Commercial Energy Storage System for AC Distribution Integration
Voltertech 57.6kWh 25kVA commercial BESS with 230/400V AC interface, 36.2A rated current, 576V LiFePO4 battery and optional dual-channel PV input. For installers planning commercial electrical distribution and solar integration. -
107kWh LiFePO4 Battery 50kVA Hybrid Solar Energy System with Integrated Battery and PCS Cabinet
107kWh 50kVA Hybrid Solar Energy System with LiFePO4 Battery The Voltertech BESS-107KWH-50KW-W is an integrated energy storage solution for hybrid solar projects requiring higher battery capacity and stable power conversion. It combines 107kWh LiFePO4 battery storage with 50kVA rated power in one ...