Liquid Cooling Commercial Energy Storage System with Integrated 156kW PV Input and 20ms STS Transfer Solar Plus Storage Cabinet

Product Summary
215kWh commercial solar plus storage cabinet with integrated 156kW PV input and 100kW PCS. Liquid cooled, on/off-grid with 20ms transfer, diesel generator linkage and 3-unit parallel operation. Simplifies PV plus storage projects for EPC contractors. OEM available.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: IEC62477-1 , IEC61000-6/2/4 , UN3536
Model Number: BESS-215KWH-100KW-W-4
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

215kWh Commercial Solar Plus Storage Cabinet With Integrated PV Input

A conventional commercial solar-plus-storage project needs several separate pieces of equipment: a solar inverter, a battery bank, a PCS, a transfer switch and a control system. Each connection is a design decision, a commissioning step and a potential point of failure.

The Voltertech BESS-215KWH-100KW-W takes a different approach. It integrates 156kW of PV input directly into the same liquid-cooled cabinet that holds 215kWh of LiFePO4 storage and a 100kW PCS. Solar strings connect straight to the system, so EPC contractors can deliver a complete solar-plus-storage installation from one enclosure.

The cabinet also supports grid-connected and off-grid operation, a 20ms transfer time, diesel generator linkage and parallel operation of up to 3 units — making it suited to sites that need solar, storage and dependable power in a single coordinated system.

Key Advantages for Integrated Solar Storage Projects

156kW PV Input Built In Two PV channels with an 180–800V MPPT range let solar strings connect directly to the cabinet, without a separate solar inverter.
215kWh Plus 100kW PCS Storage and power conversion share one cabinet, reducing equipment count, wiring and commissioning time on site.
On/Off-Grid Ready Automatic 20ms transfer, diesel generator linkage and 3-unit parallel capability for demanding or remote sites.

How Integrated PV Input Simplifies System Design

In a standard configuration, the solar inverter and the battery PCS are separate devices sharing an AC bus. The installer must coordinate two sets of protection, two communication interfaces and two manufacturer specifications. In this system, solar charging and battery conversion are managed inside one enclosure.

That integration has practical effects. There is less floor space used, fewer cables to terminate, and one communication point through LAN, RS485 or CAN. For contractors delivering multiple similar sites — factories, rural facilities, telecom or service stations — a standardized cabinet makes repeat installations faster and easier to support.

Design Note: Integration does not remove PV string engineering. Module Voc, Vmp, string length and current must still be checked against the input specifications before finalizing the array layout.

Solar, Storage and Grid Operating Scenarios

Direct Solar Charging

PV strings feed the cabinet directly, charging the 215kWh battery bank and supplying site loads without an intermediate solar inverter.

On-Grid Operation

The system operates at AC 380/400V with the grid present, supporting self-consumption and peak management from the same storage platform.

Off-Grid and Generator Supported

With 20ms grid-to-off-grid transfer and diesel generator linkage, the system maintains supply at remote or unstable-grid sites.

Where a Cabinet With PV Input Fits Best

This configuration is most valuable where the project includes both new solar generation and storage, and where the site wants a single point of responsibility. Typical cases include factories adding rooftop PV, rural facilities replacing generator runtime with solar, and EPC contractors delivering standardized energy systems across multiple locations.

For projects where solar already exists with a functioning inverter, a storage-only cabinet may be the more economical choice. The deciding factor is whether the solar equipment is being installed new or reused.

Core Technical Specifications

Swipe left or right to view the complete specification table.

Parameter Specification
Model BESS-215KWH-100KW-W
System Type Liquid-Cooled Solar Plus Storage Cabinet
Battery Chemistry LiFePO4
Total Capacity 215kWh
Nominal Capacity (Cell) 280Ah
Nominal Voltage 768V
Operating Voltage Range 648V – 864V
Nominal Charge / Discharge Current 140A
Max. PV Input Power (2 Channels) 156kW
MPPT Voltage Range 180V – 800V
PCS Rated Output Power (On-Grid / Off-Grid) 100kW
Rated AC Voltage (On-Grid) AC 380/400V, 50/60Hz
Rated AC Voltage (Off-Grid) 220/230/380/400V
Degree of Unbalance 100%
STS Transfer Time 20ms
Diesel Generator Function Generator linkage supported
Maximum Efficiency 98%
Parallel Operation Up to 3 Units
Cooling Mode Liquid Cooling
Cycle Life / Calendar Life 8000 Cycles / 15 Years
Enclosure Protection IP54
Operating Temperature -20°C to +60°C
Communication LAN / RS485 / CAN
Dimensions (L × W × H) 1385 × 910 × 2203mm
Net Weight Approx. 2.2 T

System Integration and Project Considerations

PV Array Planning
Verify PV string voltage and current against the integrated MPPT input range before module layout is fixed. Two PV channels allow separate string groups.
Grid and Load Side
On-grid output is AC 380/400V; off-grid configurations support 220/230/380/400V. Confirm local voltage and unbalance requirements during design.
Transfer and Continuity
The 20ms STS transfer supports sensitive equipment during grid interruptions. Verify site protection coordination with the electrical contractor.
Generator Coordination
Where a diesel generator exists, the linkage function allows coordinated operation to reduce runtime and fuel consumption.
Site Layout
The cabinet measures 1385 × 910 × 2203mm and weighs approximately 2.2 tonnes. Allow service clearance and access to the liquid-cooling system.

Typical Integrated Solar Storage Applications

Factories Adding Rooftop Solar

Solar, storage and power conversion delivered in one cabinet for sites that want to install generation and storage together.

Rural Facilities and Remote Sites

Solar-led power with battery storage and generator linkage for locations where grid supply is limited or absent.

Telecom and Service Infrastructure

Continuity for equipment sites needing fast transfer between grid, storage and generator sources.

Repeat EPC Projects

Standardized solar-plus-storage deployments across multiple sites, reducing design and commissioning variation between locations.

Frequently Asked Questions

Q1. Do I need a separate solar inverter with this cabinet?

No. Solar strings connect directly to the integrated PV input on the cabinet, which manages solar charging and battery conversion in one system. String design must still be checked against the input limits.

Q2. Can the system operate without the grid?

Yes. The system supports both on-grid and off-grid operation, with AC output options of 220/230/380/400V in off-grid mode, subject to the approved configuration for the project.

Q3. What does the 20ms transfer time mean for my site?

It describes how quickly the system can switch between grid and battery supply during an interruption, reducing disruption to connected equipment. Site protection coordination should still be reviewed by the electrical contractor.

Q4. Can this cabinet work with an existing diesel generator?

Yes. Generator linkage is supported, allowing the solar-plus-storage system to coordinate with diesel generation and reduce runtime where generation and battery capacity are sufficient.

Q5. How does this differ from other 215kWh cabinets in the series?

This model includes integrated PV input, off-grid output options, fast transfer and generator linkage — features oriented toward complete solar-plus-storage projects. Other cabinets in the series focus on grid-connected commercial applications. The right choice depends on whether the project includes new solar generation and off-grid requirements.

Q6. Can multiple cabinets be used for a larger site?

Yes. Up to 3 units can operate in parallel for larger installations, coordinated through the communication interfaces.

Q7. What information is needed for a solar plus storage quotation?

Please provide the destination country, planned PV array size and module specifications, site voltage and grid conditions, essential load list, generator details if any, and the required number of cabinets. A site layout or single-line diagram helps with system design.

Planning an Integrated Solar Plus Storage Project?

Voltertech supplies liquid-cooled solar-plus-storage cabinets for EPC contractors, distributors and project developers. Share your PV plan, site conditions and load requirements for system design and quotation.

OEM options are available for regional partners and repeat project deployments.

Request 215kWh Solar Storage Cabinet Details & Quotation
Product Details
Highlight:

Integrated 156kW PV Input Commercial Energy Storage System

,

Liquid Cooling Solar Plus Storage Cabinet

,

20ms STS Transfer Commercial Energy Storage System

Application: Solar Plus Storage / Off-Grid
Target Buyers: EPC, Distributors, Integrators
Key Feature: Integrated 156kW PV Input
PCS Output: 100kW On/Off-Grid
Transfer Time: 20ms STS
Parallel: Up To 3 Units
Cooling: Liquid Cooling
Supply Type: OEM / Project Support

Customer Service

Related Products
Send An Inquiry