1.25MW 10kV Energy Storage PCS Power Conversion System for Power Quality Coordination

Product Summary
Voltertech 1.25MW 10kV transformer-isolated power conversion container with 1250kVA AC rating, power factor adjustment from -1 to +1 and ≤3% THD at rated power. For EPC engineers assessing grid power quality and dispatch control.
Basic Properties
Place of Origin: China
Brand Name: Voltertech
Certification: IEC62477-1 , IEC61000-6/2/4 , UN3536
Model Number: BESS-125MW-W-3
Trading Properties
Minimum Order Quantity: 1 Unit
Price: Negotiable
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Units per Month
Product Description

1.25MW 10kV Energy Storage PCS for Power Quality Coordination

In a medium-voltage battery energy storage project, electrical engineers must evaluate more than the rated conversion power. Grid connection studies may also require harmonic performance data, reactive power capability, protection coordination and verification of dispatch commands.

The Voltertech BESS-125MW-W is a transformer-isolated, AC-side containerized power conversion system rated at 1250kW on the DC side and 1250kVA on the AC side. Its 10kV interface, adjustable power factor specification and dispatch communication options make it suitable for technical evaluation in MW-scale energy storage projects.

GRID ENGINEERING PARAMETERS AT A GLANCE

10kV

Rated AC Voltage

1250kVA

Rated AC Apparent Power

≤3%

THD at Rated Power

Understanding Harmonic Performance in a 10kV BESS Project

The equipment specification lists maximum total harmonic distortion of no more than 3% at rated power. This is an important reference when preparing the power quality section of a grid connection study.

However, a rated-power harmonic value should not be interpreted as guaranteed harmonic performance under every partial-load condition. It also does not, by itself, demonstrate compliance with the harmonic limits at the project's point of common coupling.

Grid engineers should confirm the harmonic measurement definition, applicable operating conditions and any additional study requirements imposed by the utility or local grid code.

Reactive Power and Power Factor Coordination

The BESS-125MW-W specifies an adjustable power factor range from -1 to +1. This allows the equipment to be evaluated for projects where reactive power behavior forms part of the grid connection requirements.

For practical system design, the complete active-power and reactive-power operating limits must be verified. The stated power factor range does not automatically mean that maximum active output and maximum reactive output can be delivered simultaneously.

Project engineers should request the approved P-Q capability information, control-mode details and applicable operating limitations before committing to a reactive power requirement.

Dispatch Commands, Feedback and Control Verification

The system provides CAN and RS485 for battery-side communication, while dispatch communication includes Modbus RTU, Modbus TCP and IEC 60870-5-104.

For an energy storage plant, identifying an available protocol is only the beginning. The integration team must also verify the relevant command points, measurements, device status indications, permissions and alarm handling.

A clear communication test plan helps determine whether the selected PCS, supervisory controller and battery system can operate together according to the project requirements.

Power Quality and Grid-Control Review Checklist

The following engineering checklist can help EPC contractors prepare for a medium-voltage connection review. It describes items to verify, not completed certifications or factory test results.

Review Item Information to Confirm
Harmonic Performance Measurement conditions, harmonic limits and utility study requirements
Reactive Power P-Q capability, permitted control modes and operating limits
Dispatch Integration Protocol mapping, setpoint behavior, status feedback and alarm handling
MV Protection Relay settings, transformer protection and earthing arrangement

Core Technical Specifications

Parameter Specification
Rated DC Power 1250kW (1.25MW)
DC Operating Voltage Range 1000–1500V
Maximum DC Current 1309A
Rated AC Apparent Power 1250kVA
Rated AC Voltage / Current 10kV / 72.5A
Isolation Mode Transformer Isolation
Maximum THD ≤3% at Rated Power
Power Factor Range Adjustable from -1 to +1
Dispatch Communication Modbus RTU / TCP / IEC 60870-5-104
Container Dimensions / Net Weight 5523 × 2400 × 2800mm / Approx. 6000kg

Preparing for Medium-Voltage Grid Acceptance

Before commissioning, the project team should define the applicable connection standards, utility approval procedures and required performance verification.

The AC-side container should be reviewed together with the selected battery system, site protection equipment and plant controller. Important engineering inputs include the approved electrical single-line diagram, grid operating requirements, relevant power quality studies and a coordinated commissioning plan.

The equipment's rated 10kV interface and transformer isolation are technical design characteristics; they do not remove the need for project-specific grid connection approval.

Power Quality & Grid Commissioning FAQs

Q1. Does the ≤3% THD specification apply at every operating power level?

The stated value applies at rated power. Harmonic behavior at other operating conditions and at the project's point of common coupling must be reviewed against the applicable grid code and approved test data.

Q2. Can the PCS deliver full reactive power while also delivering rated active power?

The specification lists a power factor adjustment range of -1 to +1, but the simultaneous active and reactive power limits are not defined by that range alone. Engineers should request the approved P-Q capability curve and control specifications.

Q3. How should dispatch setpoints be verified during commissioning?

The project test plan should verify supported command points, permitted operating modes, feedback values, communication status and alarm responses. Actual tests must follow the approved communication map and system control design.

Q4. Is the equipment's harmonic rating sufficient to demonstrate utility grid-code compliance?

No. Utility acceptance may require studies or measurements at a defined grid connection point, including the effects of other equipment and local operating conditions. The project engineer should confirm the required methods and limits with the relevant utility.

Q5. Which protection studies are important before energizing the 10kV connection?

Typical reviews may include short-circuit calculations, relay coordination, transformer protection, grounding or earthing arrangements and the approved single-line diagram. The exact study scope depends on the project and local interconnection requirements.

Review Your 1.25MW / 10kV Grid Integration Requirements

Send Voltertech your medium-voltage single-line diagram, grid code requirements, power quality targets and dispatch communication specifications. Our team can discuss the relevant equipment parameters and technical documentation for your project.

Request Power Quality & PCS Details
Product Details
Highlight:

1.25MW Energy Storage PCS

,

10kV Power Conversion System

,

Power Quality Coordination PCS

Product Positioning: MV Grid-Support Power Conversion
Target Buyers: Utility EPCs / Electrical Integrators
Project Stage: Grid Connection Engineering Review
Power Quality Focus: Harmonic Performance Assessment
Reactive Power Planning: Active / Reactive Power Coordination
Control Acceptance: Dispatch Setpoint Verification
Protection Engineering: MV Relay & Earthing Coordination
MV Relay & Earthing Coordination: Grid Code / SLD / Test Plan