7.68kWh 3.6kW Off Grid Solar Energy Storage System With Dual AC Outputs
7.68kWh 3.6kW Off Grid Solar Energy Storage System with Dual AC Outputs
This off grid solar energy storage system combines a 7.68kWh LiFePO4 battery with a 3.6kW inverter and MPPT charging. It provides a balanced energy reserve for remote homes, shops, offices and other sites with controlled day-and-night loads.
Balance Daily Consumption and Night Reserve
The larger battery provides more potential operating time than the entry configuration. Essential equipment should still be calculated from wattage and daily operating hours.
Flexible equipment can be scheduled during stronger solar production, preserving stored energy for evening lighting, refrigeration, communications and other priority loads.
Solar Charging with Generator Support
The MPPT input operates from 60–500Vdc, with a maximum open-circuit voltage of 500Vdc and a photovoltaic input-current limit of 18A.
A compatible generator or utility source can provide charging during poor solar conditions. Generator voltage, frequency and continuous capacity should meet the inverter input requirements.
Organize Local Loads through Two Outputs
Two AC channels can separate priority circuits from loads that may be switched off when battery energy is limited. The combined AC output remains 3.6kW.
Grid export and parallel-machine operation are not supported. The system is intended to supply local loads from one integrated unit.
7.68kWh Off-Grid Technical Data
| Stored Energy | 7.68kWh / 25.6V / 300Ah LiFePO4 |
| Local Load Output | 3.6kW Rated / 5400VA Instantaneous |
| AC Output Quality | 220/230Vac ±5% / 50 or 60Hz / Pure Sine Wave |
| PV Input Window | 60–500Vdc MPPT / 500Vdc Maximum Voc / 18A |
| AC Charging Source | 230Vac / Automatic 50–60Hz Detection |
| Battery Current Rating | 100A Maximum Charge / 150A Maximum Discharge |
| Battery Stack | Base Battery plus One Expansion Section |
| System Interfaces | RS232 / RS485 / CAN / LCD |
| Operating Location | IP22 / Dry Indoor or Protected Technical Area |
7.68kWh Off-Grid System FAQ
Is this suitable for overnight essential loads?
Suitability depends on total overnight energy consumption and the reserve retained by the system.
Can loads operate while solar energy charges the battery?
Available solar power can support local loads and battery charging according to system conditions and settings.
Can a generator be used during cloudy weather?
Yes, when the generator output meets the inverter’s voltage, frequency and power requirements.
Can the system sell electricity to the grid?
No. Grid-connected export is not supported.
What determines the required solar array?
Daily energy use, effective sunlight, panel voltage and required battery recovery time determine the array design.
Review Daytime Charging and Night Loads
Send your daytime and overnight load schedule. We will assess whether 7.68kWh provides sufficient usable reserve.
Off Grid Solar Energy Storage System
,3.6kW Solar Energy Storage System
-
61.44kWh 12kW All In One Energy Storage System With Modular Battery Stack
61.44kWh 12kW All in One Energy Storage System with Modular Battery Stack This all in one energy storage system combines a 61.44kWh LiFePO4 battery stack with a 12kW pure sine wave inverter, dual MPPT charging and two AC output channels. It is the largest battery configuration in this product range ... -
Five Module All In One ESS Energy Storage System 12kW 25kWh With Dual MPPT
Five-Module 12kW 25kWh All In One Energy Storage System with Dual MPPT Modular All In One ESS for Medium-to-High Capacity Projects This 12kW 25kWh all in one energy storage system combines pure sine wave inverter output, five stackable LiFePO4 battery modules, dual MPPT solar charging, dual AC ... -
10.24kWh 51.2V Residential Energy Storage Battery With 200A Charging
10.24kWh 51.2V Residential Energy Storage Battery with 200A Charging This residential energy storage battery provides 10240Wh of stated LiFePO4 storage capacity for home solar and backup projects. Its larger battery format is intended for households that need more evening energy, a stronger backup ...